Electrical Engineer (Power Transmission-Testing&Commissioning) |
Resume built for oil and gas job opportunities by a jobseeker with experience in Electrical Engineer (Power Transmission-Testing&Commissioning) - would you like to offer this candidate a job/contract employment? Please contact us OR search for another relevant oil CV/Resume in our impressive oil industry database
CV/Resume ID no.:
79387
|
Location (Residence): Dubai, United Arab Emirates
Citizenship: India
|
|
Languages:
Native:
Hindi Other:
Hindi |
|
Education & Experience: |
Work Authorization & Relocation: |
|
Education:
Bachelors in Electrical&Electronics Years of Experience:
7 years
|
Authorized to work in:
Bahrain, India, Kuwait, Oman, Qatar, Saudi Arabia, United Arab Emirates
Present Location:
UAE, UAE
Relocation:
UK (in particular), United States, Australia, Canada, India, Oman, Qatar, Saudi Arabia, United Arab Emirates, United States |
|
|
Expertise |
Category |
Subcategory |
Ability |
Experience |
Engineering |
Electrical |
Experienced
|
12 years |
Engineering |
Commissioning (+ Pre-) |
Experienced
|
2 years |
Engineering |
Electrical |
Basic
|
3 years |
|
|
CV/Resume Details |
|
1. Summary (Cover Letter) - CV/Resume Part 1 [Mandatory] |
SUB: Application For The Post Of Electrical Engineer (Power Transmission)
I am a graduate in Engineering(Electrical & Electronics) having a work experience in Power System of about 7 years.Now I am working in Dubai Electricity& Water Authority(DEWA) and for better carrier I would like to be considered for the above post and hereby forward my resume for your reference.
|
2. Work Experience - CV/Resume Part 2 [Mandatory] |
1. Company : Dubai Electricity & Water Authority(DEWA)
Designation : Assistant Engineer(Transmission Protection)
Duration : December 2006 - Present
Job Responsibilities:
Protection Maintenance of 400/132/11 KV Substations
Commissioning witness of 132/11KV Substations( CD-P)
Protection Maintenance-Nature Of Job
Routine Maintenance - Relay Testing.
In-house project commissioning witness
Online Protection Setting Change /Testing.
Attending Emergency call duty
Commissioning Witness-Nature Of Job
Test report verification,testing&commissioning of HV/LV CT,VT,NCT, Notification of Defects, Drawing Mark up, Component & Scheme Test verification,Sensitivity&Stability Test, End To End Test, Final snag clearance inspection for EHV/HV Substation contracts, consisting,
Line Feeder, Transformer Feeder, Reactor bays, Bus Coupler, Bus section.
Bus bar Protection Panels and CBF Protection
In House Protection Modification projects – MV/HV/EHV.
Testing Exposure
Relays: Main / Back up / Auxiliary relays of make Alstom, Areva, Siemens,ABB, Reyrolle
Scheme - MV/HV/EHV: CT /VT Circuit checks, DC Scheme checks, Trip Circuit Checks, Trip Logic Checks, SCADA signaling check, Inter trip Logic check, Transformer Sensitivity & Stability Test, Bus bar Protection Sensitivity / Stability Test, CBF Scheme and Trip logic test.
Test Equipments & Instruments:
Primary Injection Test Kit : Programma T & R
Secondary Injection Test Kit : Omicron CMC – 256-6,CMC-156, ISA1000,
Swerker- 760, SMC
2. Company : Modern Rajab Construction
Designation : Site Engineer(Protection Commissioning)
Duration : 29-March-2004 to 13-November-2006
Site handled : (i) Umm-Ul-Nar(S-18) and Abu Dhabi(E-16) 132/11 KV Substations
under Abu Dhabi Water &Electricity Authority(ADWEA)
Consultant : Lahmeyer International / Contractor : Siemens
Experience summary
Installation, testing& commissioning of 132 KV CT, VT, NCT, Protection relays-
Alstom,Areva,ABB, Siemens & Reyrolle make, Load test, Sensitivity & Stability
Test, Verification of Marked up Drawing, Test Reports and final Snag Clearance
3. Company : Kerala State Electricity Board (KSEB)
Designation : Assistant Engineer(Transmission)
Duration : 12-July-2001 to 18-March –2004
Site Handled:1) 110/33/11 KV Substation,Mannarkkad.
2) 110/11 KV Substation,Malampuzha.
3) 33/11 KV Substation,Agali.( Transmission Construction)
Experience summary
(i) Worked as Station Engineer of 110 KV Substations for Supervision of
Operation and Maintenance of all Substation Equipments. (July 2001-August 2003)
(ii) 33 KV overhead line construction and commissioning of 33/11 KV Substation,
Agali (Sep 2003 - March 2004)
Relays Tested
ABB Make SPAJ ,SPAS, REL 316*4, REL 551 ,LCB II
ALSTOM LFCB, MBCH, MBCI, MCAG, Micom P632,P543,P442, P121, P122,
/AREVA Make P125, P127, P141,MCGG, MCTI, METI, MCRI, MVAJ, MVAX,
MRTP, MVTP, MVAP, MVTT
SIEMENS Make 7SD511, 7SD503, 7SD512, 7SD612, 7UT512 ,7SJ600, 7SJ62,
7SJ531, 7RW600, 7SV512
Reyrolle Make THR , DUOBIAS, 5B3, B3 , SOLKAR-RF, 4C21,ARGUS1, 2, & 3,
2DCC, TJM Relays,2DAB, TR series, B Series, XR Series, DDB5
|
3. Education & Training - CV/Resume Part 3 [Mandatory] |
Educational Qualifications
Degree : Bachelor of Technology(B.Tech)
Discipline : Electrical & Electronics Engineering.
College : N.S.S.College of Engineering,Palakkad.
University : University of Calicut
Training Summary
AREVA Training on Numerical Relays-Micom P122,P632,P442 &P353 (Concord Hotel-Dubai-3 Days)
IDM Training of Fault Recorder by Qualitrol Corporation,UK(Renaissance hotel-Dubai-4 days)
THR-Distance(Reyrolle) and Siprotec 7SD61-Line Differential(Siemens)/(In House Training-DEWA,2 Days)
Management Training (3 Sessions)for improvement of work management by CANNIZARO, a UK based management Consultant.
Safety Training of ‘Basic Needs On Occupational Health & Safety’ and ‘Risk Assessment’.(DEWA Head Office-2 Days)
|
4. Computer Skills - CV/Resume Part 4 [Mandatory] |
Computer skills
1: Enterprise Resource planning software
Maintenance Management System & Office Management System
2: Computer languages: FORTRAN 77 & C
3: Packages : MS Office
4: International computer driving license (ICDL) Certified
|
5. Other Skills - CV/Resume Part 5 [Optional] |
Installation, testing& commissioning of 132 KV CT, VT, NCT, Protection relays-
Alstom,Areva,ABB, Siemens & Reyrolle make, Load test, Sensitivity & Stability
Test, Verification of Marked up Drawing, Test Reports and final Snag Clearance
|
6. Additional Information - CV/Resume Part 6 [Optional] |
-
|
|
|